716 research outputs found

    The application of a vacuum ultraviolet Fourier transform spectrometer and synchrotron radiation source to measurements of: IV. The β(6,0) and γ(3,0) bands of NO

    Get PDF
    The β(6,0) and the γ(3,0) bands of NO near 198 nm were analyzed using the VUV FT spectrometer with synchrotron radiation for the background source. Accurate line positions and line strengths of the rotational lines were retrieved from the FT spectra. The rotational term values of the B 2∏ r (v=6) and A 2Σ + (v=3) levels were evaluated and fed to a least squares fitting program to obtain accurate molecular constants of these levels.published_or_final_versio

    Application of a VUV fourier transform spectrometer and synchrotron radiation source to measurements of. VI. The ε(0,0) band of NO

    Get PDF
    The analysis of the ε(0,0) band around 187.6 nm was reported using the VUV FTS with synchrotron radiation for the background source. Due to the capability of the combintion of instruments, These were the first high-resolution quantitative measurements of line positions and intensities of the rotational lines of the ε(0,0) band. The determination of the band oscillator strengths of the band was performed using line-by-line measurements, because the resolution of the present experiment was comparable to the Doppler widths.published_or_final_versio

    Hall viscosity from gauge/gravity duality

    Full text link
    In (2+1)-dimensional systems with broken parity, there exists yet another transport coefficient, appearing at the same order as the shear viscosity in the hydrodynamic derivative expansion. In condensed matter physics, it is referred to as "Hall viscosity". We consider a simple holographic realization of a (2+1)-dimensional isotropic fluid with broken spatial parity. Using techniques of fluid/gravity correspondence, we uncover that the holographic fluid possesses a nonzero Hall viscosity, whose value only depends on the near-horizon region of the background. We also write down a Kubo's formula for the Hall viscosity. We confirm our results by directly computing the Hall viscosity using the formula.Comment: 12 page

    The application of a VUV Fourier transform spectrometer and synchrotron radiation source to measurements of: II. The δ(1,0) band of NO

    Get PDF
    Line-by-line photoabsorption cross-sections of the NO δ(1,0) band were measured with the VUV Fourier transform spectrometer from Imperial College, London, using synchrotron radiation at Photon Factory, KEK, Japan, as a continuum light source. The analysis of the NO δ(1,0) band provides accurate rotational line positions and term values as well as the photoabsorption cross-sections. The molecular constants of the C(1)2 II level are found to be T0 = 54 690.155±0.03 cm–1, Bv = 1.944 06±0.000 62 cm–1, Dv = (5.91±0.42)×10–5 cm–1, AD = –0.0187±0.0050 cm–1, p = –0.0189±0.0037 cm–1, and q = –0.015 21±0.000 20 cm–1. The sum of the line strengths for all rotational transitions of the NO δ(1,0) band is determined as 4.80×10–15 cm2 cm–1, corresponding to a band oscillator strength of 0.0054±0.0003.published_or_final_versio

    Evaluation of early and late presentation of patients with ocular mucous membrane pemphigoid to two major tertiary referral hospitals in the United Kingdom

    Get PDF
    PURPOSE: Ocular mucous membrane pemphigoid (OcMMP) is a sight-threatening autoimmune disease in which referral to specialists units for further management is a common practise. This study aims to describe referral patterns, disease phenotype and management strategies in patients who present with either early or established disease to two large tertiary care hospitals in the United Kingdom.\ud \ud PATIENTS AND METHODS: In all, 54 consecutive patients with a documented history of OcMMP were followed for 24 months. Two groups were defined: (i) early-onset disease (EOD:<3 years, n=26, 51 eyes) and (ii) established disease (EstD:>5 years, n=24, 48 eyes). Data were captured at first clinic visit, and at 12 and 24 months follow-up. Information regarding duration, activity and stage of disease, visual acuity (VA), therapeutic strategies and clinical outcome were analysed.\ud \ud RESULTS: Patients with EOD were younger and had more severe conjunctival inflammation (76% of inflamed eyes) than the EstD group, who had poorer VA (26.7%=VA<3/60, P<0.01) and more advanced disease. Although 40% of patients were on existing immunosuppression, 48% required initiation or switch to more potent immunotherapy. In all, 28% (14) were referred back to the originating hospitals for continued care. Although inflammation had resolved in 78% (60/77) at 12 months, persistence of inflammation and progression did not differ between the two phenotypes. Importantly, 42% demonstrated disease progression in the absence of clinically detectable inflammation.\ud \ud CONCLUSIONS: These data highlight that irrespective of OcMMP phenotype, initiation or escalation of potent immunosuppression is required at tertiary hospitals. Moreover, the conjunctival scarring progresses even when the eye remains clinically quiescent. Early referral to tertiary centres is recommended to optimise immunosuppression and limit long-term ocular damage.\ud \u

    The application of a VUV Fourier transform spectrometer and synchrotron radiation source to measurements of: I. the β(9,0) band of NO

    Get PDF
    State-of-the-art models of the vacuum ultraviolet (VUV) absorbing properties of the atmosphere call for absorption cross sections with detail on the scale of the Doppler widths. As a consequence, spectroscopic data at resolving powers of the order of 10 6 are needed. To meet these requirements in the vacuum ultraviolet region, we have used the VUV Fourier transform spectrometer from Imperial College, London, at the synchrotron radiation facility at Photon Factory, KEK, Japan, to measure photoabsorption cross sections of NO from 195 to 160 nm, and of O 2 from 185 to 175 nm. The analysis of the β(9,0) band (B 2Π r-X 2Π r) of NO provides accurate rotational line positions and term values. Molecular constants of the B(9) 2Π level are T 0=54205.097±0.012cm -1, A=45.320±0.021cm -1, B υ=1.01672±0.00016cm -1, D υ=(10.61±0.32)×10 -6cm -1, and A D=0.00122±0.00011cm -1. The rotational line strengths and the branching ratios are also presented. The band oscillator strength is obtained as f=2.65×10 -4. © 1998 American Institute of Physics.published_or_final_versio

    Classification Criteria for Multiple Sclerosis-Associated Intermediate Uveitis

    Get PDF
    PURPOSE: The purpose of this study was to determine classification criteria for multiple sclerosis-associated intermediate uveitis. DESIGN: Machine learning of cases with multiple sclerosis-associated intermediate uveitis and 4 other intermediate uveitides. METHODS: Cases of intermediate uveitides were collected in an informatics-designed preliminary database, and a final database was constructed of cases achieving supermajority agreement on the diagnosis, using formal consensus techniques. Cases were split into a training set and a validation set. Machine learning using multinomial logistic regression was used in the training set to determine a parsimonious set of criteria that minimized the misclassification rate among the intermediate uveitides. The resulting criteria were evaluated in the validation set. RESULTS: A total of 589 cases of intermediate uveitides, including 112 cases of multiple sclerosis-associated intermediate uveitis, were evaluated by machine learning. The overall accuracy for intermediate uveitides was 99.8% in the training set and 99.3% in the validation set (95% confidence interval: 96.1-99.9). Key criteria for multiple sclerosis-associated intermediate uveitis included unilateral or bilateral intermediate uveitis and multiple sclerosis diagnosed by the McDonald criteria. Key exclusions included syphilis and sarcoidosis. The misclassification rates for multiple sclerosis-associated intermediate uveitis were 0 % in the training set and 0% in the validation set. CONCLUSIONS: The criteria for multiple sclerosis-associated intermediate uveitis had a low misclassification rate and appeared to perform sufficiently well enough for use in clinical and translational research

    Classification Criteria for Intermediate Uveitis, Non–Pars Planitis Type

    Get PDF
    Purpose: To determine classification criteria for intermediate uveitis, non-pars planitis type (IU- NPP, also known as undifferentiated intermediate uveitis) / Design: Machine learning of cases with IU-NPP and 4 other intermediate uveitides. / Methods: Cases of intermediate uveitides were collected in an informatics-designed preliminary database, and a final database was constructed of cases achieving supermajority agreement on the diagnosis, using formal consensus techniques. Cases were split into a training set and a validation set. Machine learning using multinomial logistic regression was used on the training set to determine a parsimonious set of criteria that minimized the misclassification rate among the intermediate uveitides. The resulting criteria were evaluated on the validation set. / Results: Five hundred eighty-nine of cases of intermediate uveitides, including 114 cases of IU-NPP, were evaluated by machine learning. The overall accuracy for intermediate uveitides was 99.8% in the training set and 99.3% in the validation set (95% confidence interval 96.1, 99.9). Key criteria for IU-NPP included unilateral or bilateral intermediate uveitis with neither 1) snowballs in the vitreous nor 2) snowbanks on the pars plana. Other key exclusions included: 1) multiple sclerosis, 2) sarcoidosis, and 3) syphilis. The misclassification rates for pars planitis were 0 % in the training set and 0% in the validation set, respectively. / Conclusions: The criteria for IU-NPP had a low misclassification rate and appeared to perform well enough for use in clinical and translational research
    corecore